Displaying all papers about Prednisolone-21-hydrogen Succinate (1 results)

Release Rates of Prednisolone-21-Hydrogen- Succinate from 3D-Printed Silicone as Material for Patient-Individualized Drug Releasing Implants

Current Directions in Biomedical Engineering 2024 Volume 10, Issue 4, Pages 373-376

For treating idiopathic sudden sensorineural hearing loss, prednisolone is commonly used. However, systemic or middle ear injections often lead to insufficient drug delivery to the inner ear, causing ineffective treatment and systemic side effects. An implant inserted into the middle ear and delivering the drug directly to the inner ear offers a promising solution, providing controlled, long-term drug release with potentially better efficacy and fewer side effects. Individualized implants made of prednisolone-containing silicone can optimize inner ear treatment by fitting the patient’s middle ear anatomy. To gauge the properties of prednisolone-21-hydrogen succinate containing silicone, samples with different geometries and drug…